Autotrol i Manual – Free download as PDF File .pdf), Text File .txt) or read online for free. Valve Exploded View. Valve Parts List. Performa Exploded View. Performa Parts List. Logix Series Controllers Parts List. TROUBLESHOOTING. SWT’s online PDF library of Autotrol Control Valve Installation, Operation, Logix Operation Manual (Models: Twin Alternating, Twin.

Author: Togul Sajora
Country: Bahamas
Language: English (Spanish)
Genre: Life
Published (Last): 9 July 2013
Pages: 22
PDF File Size: 20.98 Mb
ePub File Size: 20.50 Mb
ISBN: 897-5-64381-521-4
Downloads: 70730
Price: Free* [*Free Regsitration Required]
Uploader: Tygojin

I remember seeing it in the old manuals where it showed a check valve but no real clear way to get to it.

Autotrol / Osmonics Manuals

I replaced all the flapper valves and everything works fine now. Yes I agree, I disassembled the valve, again, and soaked everything in a concentrated solution of Iron out and it is clean.

Thanks for all the helpful advice. It sounds like there is leakage past the 2 and possibly the 3 flapper valves and these are the two main valves. My main problem is iron, I thought about soaking it in a heavy concentrate of super iron out for a couple of days. I’ve never seen a bad ball.

Watts Autotrol 255 (400 Series) User Manual

Autotrol won’t draw brine Printable View. In what area is the check valve and is there anything that it can be soaked in to clean it out like Iron out.

Any advice would be greatly appreciated! When it is free anyway. If I need one do you have a valve that can be rebilt, or how much is a new valve without the timer. The ,anual part number of ATthe valve body that sets on top of the tank adapter module looks to be around While looking at the parts brake down of that valve, I see that there are some O rings between the two parts. All times are GMT After putting it back together and installing it back on the tank it still won’t siphon brine and actually water comes out of the brine well tube.

  ISTORIA IUBIRII NICOLE KRAUSS PDF

If the ball doesn’t autotroo against its seat you may get water into the salt tank. Originally Posted by kpreilly. What kind of water quality are you deal with?

autotro, I will let you know the results, thanks. With all of the flappers and other parts off one might be able to by soaking it in some thing like iron out. I have soaked it in Iron out, flushed it, cleaned the flapper valves, screen, injector valve basically everything that can come apart has come apart and been cleaned.

So I will get a rebuild kit and try that.

I have an Autotrolthe problem I am having is it is not drawing brine in fact autogrol the brine cycle it flows a small amount of water into the brine tank instead of creating the suction needed to draw brine out of the tank.

I’ve cleaned the little screen and the injector – and I’ve cleaned the air check valve base.

Autotrol Series |

Can you hear the valve move if you shake the valve body? The air check is where the brine line going to the salt tank is connected to the control valve on top the air check. I have a steady, but slow stream of water little more than a trickle coming through the drain line. I also was going to buy a rebuild kit but don’t want to waste the money if I need to replace the valve assembly.

  HP 9100C DIGITAL SENDER PDF

The time now is There is no check valve anywhere inside the Autotrol I also have an Autotrol – and the brine tank is consistently overfilling. You don’t need any new module etc. I have taken the control valve off numerous times, disassembled it and cleaned it as best I can.

Watts Autotrol ( Series) User Manual | 32 pages

I will have to check one of the valves that I have in the pile, see what it sounds like. It sounds as if you need a set of new flapper valves, especially the brine pair.

The only “check valve” is the black rubber ball in the air check on the right side facing the control. Is there anything inside the valve that I cannot get to that might be clogged or stuck and if so what can I do about it?