Fineness of Hydraulic Cement by Air Permeability Apparatus. ASTM C 11 Standard Test Methods for Fineness of Hydraulic Cement by Air Permeability Apparatus – Download as PDF File .pdf), Text File .txt) or read. ASTM C Standard Test Methods for Fineness of Hydraulic Cement by Air- Permeability Apparatus. standard by ASTM International.

Author: Arashikinos Mikasa
Country: France
Language: English (Spanish)
Genre: Photos
Published (Last): 20 March 2005
Pages: 388
PDF File Size: 5.81 Mb
ePub File Size: 20.14 Mb
ISBN: 273-2-23554-995-1
Downloads: 49500
Price: Free* [*Free Regsitration Required]
Uploader: Murisar

ASTM C204 – 17

The plunger shall be constructed of austenitic stainless steel and shall fit into the cell. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to qstm. When the specific surface values determined by an automated apparatus c20 to be used for acceptance or rejection of cement, the method used shall comply with the qualification requirements.

However, the user should exercise judgement in determining its suitability with regard to fineness measurements of cements with densities, or porosities that differ from those assigned to Standard Reference Asrm No.

Although the test method may be, and has been, used for the determination of the measures of fineness of various other materials, it should be understood that, in general, relative rather than absolute fineness values are obtained.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. The calibration of the air permeability asm shall be made using the standard reference material. The Blaine air-permeability apparatus consists essentially of a means of drawing a definite quantity of air through a prepared bed of cement of definite porosity.

This abstract is a brief summary of the referenced standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not asgm as part of the standard. Work Item s – proposed revisions of this standard. The U-tube manometer shall be constructed according to the design indicated.

  IEC 62198 PDF

ASTM C Fineness of Hydraulic Cement | CTLGroup

The automated test method shall employ apparatus designed either on the principles of the Blaine air-permeability method or apparatus based on the air-permeability principles of the Lea and Nurse method.

However, the user should exercise judgement in determining its suitability with regard to fineness measurements of cements with densities, or porosities that differ from those assigned to Standard Reference Material No. Test Method A is the Reference Test Method using the manually operated standard Blaine apparatus, while Test Method B permits the use of automated apparatus that has in accordance with the qualification requirements of this test method demonstrated acceptable performance.

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. The permeability cell shall consist of a rigid cylinder, constructed of austenitic stainless steel. The filter paper disks shall be circular, with smooth edges, and shall have the same diameter as the inside of the cell.

ASTM C Standard

The timer shall have a positive starting and stopping mechanism. When standardization is required in order to achieve agreement between test method A and test method B, the apparatus shall be standardized according to the requirements prescribed.

Historical Version s – view previous versions of standard Work Item s – proposed revisions of this standard Translated Version s: Test Method A is the Reference Test Method using the manually operated standard Blaine apparatus, while Test Method B permits the use of automated apparatus that has in accordance with the qualification requirements of this test method demonstrated x204 performance.

  B564A DATASHEET PDF

Historical Version s – view previous versions of standard. Link to Active This link will always route to the current Active version of the standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Work Item s – proposed revisions of this standard. Link to Active This link will always route to the current Active version of the standard. Two test methods are given: The disk shall be constructed of noncorroding metal, and shall fit the inside of the cell snugly.

Although the test method may be, and has been, used for the determination of the measures of fineness of various other materials, it should be understood that, in general, relative rather than absolute fineness values are obtained. The manometer shall be qstm to the midpoint line with a nonvolatile, nonhygroscopic liquid of low viscosity and density. This test method covers determination of the fineness of hydraulic cement, using the Blaine air-permeability apparatus, in terms of the specific surface expressed as total surface area in square centimetres per gram, or square metres per kilogram, of cement.

Two test methods are given: It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

Active view current version of standard. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials.